Fluke

AC Current Clamp, Model: i3000, Amperage Rating: 30/300/3000 AMP, Voltage Rating: 600 VRMS/VDC, Frequency Rating: 10 HZ - 50 KHZ (-3 DB), Measuring Range: 30 - 3000 AMP, 1/10/100 MILV/AMP Output, Operating Temperature: -20 To 90 DEG C (Head), -20 To 85 DEG C (Electronics), Impedance: 100 KOHM Minimum, Battery: (2) AA/MN 1500/LR6 Alkaline, Accuracy: 25 DEG C, Plus/Minus 1 PCT Of Range 45 - 65 HZ, Storage Temperature: -40 To 105 DEG C (Head), -20 To 85 DEG C (Electronics), Operating Humidity: 15 - 85 PCT (Non-Condensing), CAT III 600 V, BS EN 61010-1: 2001, BS EN 61010-2-032: 2002, BS EN 61010-031: 2002, EN 61326: 1998 And A1, A2 And A3, For Use With Multimeters, Recorders Or Data Loggers

MFR: Fluke
MFR #: I3000-FLEX-4PK
UPC: 095969362474
Item #: 193634
Fluke

AC Current Clamp, Model: i3000, Amperage Rating: 30/300/3000 AMP, Voltage Rating: 600 VRMS/VDC, Frequency Rating: 10 HZ - 50 KHZ (-3 DB), Measuring Range: 30 - 3000 AMP, 1/10/100 MILV/AMP Output, Operating Temperature: -20 To 90 DEG C (Head), -20 To 85 DEG C (Electronics), Impedance: 100 KOHM Minimum, Battery: (2) AA/MN 1500/LR6 Alkaline, Accuracy: 25 DEG C, Plus/Minus 1 PCT Of Range 45 - 65 HZ, Storage Temperature: -40 To 105 DEG C (Head), -20 To 85 DEG C (Electronics), Operating Humidity: 15 - 85 PCT (Non-Condensing), CAT III 600 V, BS EN 61010-1: 2001, BS EN 61010-2-032: 2002, BS EN 61010-031: 2002, EN 61326: 1998 And A1, A2 And A3, For Use With Multimeters, Recorders Or Data Loggers

MFR #: I3000-FLEX-4PK
UPC: 095969362474
Item #: 193634
Availability
Location Available Qty
Available Available to Order
$2099.99 each
Catalog Number
I3000-FLEX-4PK
Manufacturer
Fluke
Brand
Fluke
Country of Origin
Unknown
Made in USA
No
Application
For Use With Multimeters, Recorders Or Data Loggers
Frequency Rating
10 HZ - 50 KHZ (-3 DB)
Measuring Range
30 - 3000 AMP, 1/10/100 MILV/AMP Output
Special Features
4 pack; The I3000s Flex is an AC current clamp can be used to measure currents up to 3000 AMP when used in conjunction with oscilloscopes, recorders or data loggers; The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas; Ideal for current measurement on thick and hard to reach conductors without breaking the circuit; Output sensitivity (AC-coupled): 100 MILV, 10 M, 1 MILV/AMP; Linearity: 10 - 100 PCT of range, plus/minus 0.2 PCT of reading; Noise: 8 MILV AC RMS (30 AMP), 2 MILV AC rms (300/3000 AMP); Phase error: Less than plus/minus 1 DEG (45 - 65 HZ), plus/minus 10 DEG (at 20 KHZ); Position sensitivity: With cable greater than 25 MM from the coupling, plus/minus 2 PCT of range; External field with cable greater than 200 MM from the head plus/minus 1 PCT of range; 400 HR, low battery indicator or dedicated external power supply; Temperature coefficient: Plus/minus 0.08 PCT of reading per DEG C; Head circumference: 610 MM; Head cable diameter: 14.3 MM; Head bend radius 38.1 MM; Cable length (head to electronics): 6.56 FT; Output connection: 0.5 MR cable terminated with safety BNC connector; Supplied with 4 MM safety plug adapter; Weight: 180 GM (head), 190 GM (electronics); Pollution degree: 2; Use of the probe on uninsulated conductors is limited to 600 VAC rms or DC and frequencies below 1 KHZ; Maximum conductor size: 610 - 914 MM (depending on model)
Standard
CAT III 600 V, BS EN 61010-1: 2001, BS EN 61010-2-032: 2002, BS EN 61010-031: 2002, EN 61326: 1998 And A1, A2 And A3
UPC
095969362474
GTIN
00095969362474
Item Type
AC Current Clamp
Operating Temperature
-20 To 90 DEG C (Head), -20 To 85 DEG C (Electronics)
Voltage Rating
600