Controller, Harmony SCU, Rear Module panel, Dig 16 inputs/10 outputs

MFR: Schneider Electric
MFR #: HMISAC
Item #: 1254668

Controller, Harmony SCU, Rear Module panel, Dig 16 inputs/10 outputs

MFR #: HMISAC
Item #: 1254668
Availability
Location Available Qty
Available Available to Order
$1351.84 each

This rear module controller offers 16 digital inputs and 10 outputs. It is a controller with a supply voltage of 24V DC. It features CPU RISC processor, 128MB flash NAND, 128kB FRAM internal data storage and 128MB application run DRAM. It is an equipped with 1 serial link, 1 Ethernet TCP/IP - RJ45, 1 USB 2.0 type mini B, 1 USB 2.0 type A and DE-09 D-sub CANopen master bus connections. It is an IP20 (rear panel) conforming to IEC 60529, IP65 (front panel) conforming to IEC 60529 and NEMA 4X front panel rated product. The enclosure is made of PC/PBT. Its dimensions are 128mm (width) x 102mm (depth) x 50.65mm (height). It weighs 0.359kg. This product is certified by GOST, C-Tick, KCC and CULus. It meets ANSI/ISA 12-12-01, UL 508, IEC 61000-6-2 and CSA C22.2 No 213 Class I Division 2 standards. It can be installed into 1mm to 6mm thick panel. The integrated design of Harmony SCU delivers maximum functionality while keeping installation easy. The Harmony SCU (formerly known as Magelis SCU) is designed to operate with the EcoStruxure Machine Expert, delivers adequate functionality for control of small machines.

Catalog Number
HMISAC
Manufacturer
Schneider Electric
Brand
SCHNEIDER ELECTRIC
Country of Origin
China
Made in USA
No
Number of Pages
Limited by interl memory capacity
Standard
Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2;electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2;susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3;electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4;electrical fast transient/burst immunity test - test level: 1 kV (between analogue I/O and operating voltage) conforming to IEC 61000-4-4;electrical fast transient/burst immunity test - test level: 2 kV (relay wires) conforming to IEC 61000-4-4;electrical fast transient/burst immunity test - test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4;electrical fast transient/burst immunity test - test level: 1 kV (COM line) conforming to IEC 61000-4-4;electrical fast transient/burst immunity test - test level: 1 kV (CAN line) conforming to IEC 61000-4-4;surge immunity test - test level: 2 kV (po;+/- 3.5 mm 5-9 Hz) IEC 60068-2-6;1 gn 9-150 Hz) IEC 60068-2-6;147 m/s² 11 ms on DIN rail)IEC 60068-2-27;294 m/s² 6 ms on panel mounting)IEC 60068-2-27
GTIN
03595864175591