This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has spring terminals for fast and reliable wiring of safety circuits.

Manuals and Documentation

Features

  • Make any Modicon M2xx PLC as safety controller using a functional safety I/O modules
  • Modularity and easness of installation
  • Large choice of I/O system to enhance the capabilities of ModiconM2xx plc
  • Removable terminal BLOCKS for better control wires tightening
  • Spring terminals for fast and reliable wiring of safety circuits
  • Modicon TM3 is an EcoStruxure Machine I/O system
Manufacturer Part Number TM3SAF5RG
Brand Schneider Electric
Manufacturer Schneider Electric
UPC 785901968009
EAN 3606485393001
Country Of Origin FR
Amperage Rating 100 mA
Dimensions 1.72 in W x 2.87 in D x 3.7 in H
Temperature Rating -10 to 55 deg C Horizontal Installation
Type 1-Function
Voltage Rating 24 V DC
Alternative Part Number 15645996
Manufacturer Item Status Active
Country USA
Standards Approvals Can reach PL e/category 4 ISO 13849-1 2008;can reach PL e/category 4 ISO 13849-2 2012;can reach SILCL 3 IEC 62061 2005;can reach SIL 3 IEC 61508 2010;ANSI Haz Loc Class 1 Division 2 (pending);UL 61010-2-201;EAC;TÜV;RCM;CSA Haz Loc Class 1 Division 2 (pending);CSA 61010-2-201 (pending);ISO 13849-1:2008;ISO 13849-2:2012;IEC 62061:2005;IEC 61508:2010;IEC 60947-5-1:2010;IEC 61131-2:2007;IEC 60204-1:2005;IEC 60204-1:2009/A1;IEC 61010-1:2010;EN 50581:2012;Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2;electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2;susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3;susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3;susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3;magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8;electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4;electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4;1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5;conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6;;EFUP 10;CE;UL;EAC;RCM;CSA;TÜV
Application For emergency stop and switch monitoring
Number Of Outputs 3