RFG5DY Cool Boot Raised Floor Air Sealing Grommet, For Use With PatchRunner/NetRunner Vertical Cable Manager and Net-Access Cabinet, 4.7 in Dia Maximum Bundle, #10 (M5) Screw, Fabric/Polycarbonate, Navy Blue
- MFR:
- Panduit
- MFR #:
- RFG5DY
- UPC:
- 074983108251
- Item #:
- 770701
RFG5DY Cool Boot Raised Floor Air Sealing Grommet, For Use With PatchRunner/NetRunner Vertical Cable Manager and Net-Access Cabinet, 4.7 in Dia Maximum Bundle, #10 (M5) Screw, Fabric/Polycarbonate, Navy Blue
- MFR #:
- RFG5DY
- UPC:
- 074983108251
- Item #:
- 770701
Availability
| Location | Available Qty |
|---|---|
| Available | Available to Order |
All raised floor cutouts that allow communications cable to pass through in the hot aisle/cold aisle environment of a data center shall be equipped with a grommet to minimize bypass airflow. This grommet shall provide sealing properties for multiple cable bundles placed anywhere within the cable cutout. The grommet shall be designed to allow for new and retrofit applications and shall be available in multiple sizes to allow compatibility with vertical cable managers and cabinets. A low-profile design is required that shall not have rigid features higher than 0.71 in above the raised floor surface. The inside edge of the hole in the raised floor shall be covered to protect cables from abrasion as they pass through the raised floor.
Manuals and Documentation
Features
- Enables two or more bundles to be separated, providing ability to run power and data in the same opening while preventing degradation of cable performance
- Houses fabric, securing product to raised floor tile, slit allows for retrofit installations even when vertical cable managers are already in place
- Utilized on new installations to cover sharp edges of cut floor tile to prevent damage to cable
- Meet requirements to assure compliance with codes and standards for maximum performance, enable grommet to attach to floor while providing a pathway to ground
- Less than 5 in dia required hole cutout
- For new installations
- Integral gasket protects cables from abrasion against cut raised floor tile
- #10 (M5) screw mounting method
- Airtight fabric minimizes bypass airflow through cutouts in the raised floor tile to improve cooling of network equipment and prevents debris from falling below raised floor
- Electrostatic dissipating materials provide a pathway to ground to reduce the chance of corrupting network equipment with electric shock
- Hook and loop cinch tie provides closure at top of fabric to prevent air from escaping around cable bundles
- Vertical hook and loop material allows installation on existing cable bundles for greater system flexibility
- Integrated horizontal hook and loop closure system - enables two or more bundles to be separated, providing ability to run power and data in the same opening while preventing degradation of cable performance
- Flexible polycarbonate outer ring - houses fabric, securing product to raised floor tile, slit allows for retrofit installations even when vertical cable managers are already in place
- Flexible integral gasket - utilized on new installations to cover sharp edges of cut floor tile to prevent damage to cable
- Flame-retardant materials - meet requirements to assure compliance with codes and standards for maximum performance
- Screw holes enable grommet to attach to floor while providing a pathway to ground
| Manufacturer Part Number | RFG5DY |
| Brand | Panduit® |
| Manufacturer | Panduit |
| UPC | 074983108251 |
| Country Of Origin | CR |
| Color | Navy Blue |
| Dimensions | 6.5 in Dia x 4.5 in W x 0.6 in D |
| Material | Fabric/Polycarbonate |
| Specifications | 4.7 in Dia Maximum Bundle, #10 (M5) Screw |
| Suitable For Use With | PatchRunner™/NetRunner™ Vertical Cable Manager and Net-Access™ Cabinet |
| Type | Raised Floor |
| Alternative Part Number | 9987232 | 9986622 |
| Manufacturer Item Status | Active |
| Country | USA/Canada |
| Standards Approvals | RoHS Compliant per European Directive 2002/95/EC on the Restriction of Hazardous Substances; UL94 Standard, V-0; FAR 25.853 | ARRA Compliant | Buy American Act Compliant | RoHS Compliant |
| Application | For hot aisle or cold aisle environments in a data center where cables pass through a cut-out in the raised floor |