TM3SAC5R Modicon 1-Function Safety Module, 3 Outputs
- MFR:
- Schneider Electric
- MFR #:
- TM3SAC5R
- UPC:
- 785901968061
- Item #:
- 607859
TM3SAC5R Modicon 1-Function Safety Module, 3 Outputs
- MFR #:
- TM3SAC5R
- UPC:
- 785901968061
- Item #:
- 607859
Availability
| Location | Available Qty |
|---|---|
| Available | Available to Order |
This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches to conform to PLd / Category 3. It meets the requirements of PL d/Category 3 conforming to EN/ISO 13849-1 and SILCL 2 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.
Manuals and Documentation
Features
- Make any Modicon M2xx PLC as safety controller using a functional safety I/O modules
- Modularity and easness of installation
- Large choice of I/O system to enhance the capabilities of ModiconM2xx plc
- Removable terminal BLOCKS for better control wires tightening
- Modicon TM3 is an EcoStruxure Machine I/O system
- Modicon TM3 expansion modules are designed with a simple interlocking assembly mechanism
| Manufacturer Part Number | TM3SAC5R |
| Brand | Schneider Electric |
| Manufacturer | Schneider Electric |
| UPC | 785901968061 |
| EAN | 3606485392974 |
| Country Of Origin | US |
| Amperage Rating | 100 mA |
| Dimensions | 1.72 in W x 2.87 in D x 3.7 in H |
| Temperature Rating | -10 to 55 deg C Horizontal Installation |
| Type | 1-Function |
| Voltage Rating | 24 V DC |
| Alternative Part Number | 15645993 |
| Manufacturer Item Status | Active |
| Country | USA |
| Standards Approvals | Can reach PL d/category 3 ISO 13849-1 2008;can reach PL d/category 3 ISO 13849-2 2012;can reach SILCL 2 IEC 62061 2005;can reach SIL 2 IEC 61508 2010;TÜV;CSA 61010-2-201 (pending);CSA Haz Loc Class 1 Division 2 (pending);RCM;ANSI Haz Loc Class 1 Division 2 (pending);EAC;UL 61010-2-201;ISO 13849-1:2008;ISO 13849-2:2012;IEC 62061:2005;IEC 61508:2010;IEC 60947-5-1:2010;IEC 61131-2:2007;IEC 60204-1:2005;IEC 60204-1:2009/A1;IEC 61010-1:2010;EN 50581:2012;Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2;electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2;susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3;susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3;susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3;magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8;electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4;electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4;1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5;conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6;;EFUP 10;RCM;CSA;UL;TÜV;CE;EAC |
| Application | For emergency stop and switch monitoring |
| Number Of Outputs | 3 |
| Terminal Type | Screw |