TM3SAC5R Modicon 1-Function Safety Module, 3 Outputs

MFR:
Schneider Electric
MFR #:
TM3SAC5R
UPC:
785901968061
Item #:
607859

Availability

Location Available Qty
Available Available to Order
$562.43 each

This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches to conform to PLd / Category 3. It meets the requirements of PL d/Category 3 conforming to EN/ISO 13849-1 and SILCL 2 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.

Manuals and Documentation

Features

  • Make any Modicon M2xx PLC as safety controller using a functional safety I/O modules
  • Modularity and easness of installation
  • Large choice of I/O system to enhance the capabilities of ModiconM2xx plc
  • Removable terminal BLOCKS for better control wires tightening
  • Modicon TM3 is an EcoStruxure Machine I/O system
  • Modicon TM3 expansion modules are designed with a simple interlocking assembly mechanism
Manufacturer Part Number TM3SAC5R
Brand Schneider Electric
Manufacturer Schneider Electric
UPC 785901968061
EAN 3606485392974
Country Of Origin US
Amperage Rating 100 mA
Dimensions 1.72 in W x 2.87 in D x 3.7 in H
Temperature Rating -10 to 55 deg C Horizontal Installation
Type 1-Function
Voltage Rating 24 V DC
Alternative Part Number 15645993
Manufacturer Item Status Active
Country USA
Standards Approvals Can reach PL d/category 3 ISO 13849-1 2008;can reach PL d/category 3 ISO 13849-2 2012;can reach SILCL 2 IEC 62061 2005;can reach SIL 2 IEC 61508 2010;TÜV;CSA 61010-2-201 (pending);CSA Haz Loc Class 1 Division 2 (pending);RCM;ANSI Haz Loc Class 1 Division 2 (pending);EAC;UL 61010-2-201;ISO 13849-1:2008;ISO 13849-2:2012;IEC 62061:2005;IEC 61508:2010;IEC 60947-5-1:2010;IEC 61131-2:2007;IEC 60204-1:2005;IEC 60204-1:2009/A1;IEC 61010-1:2010;EN 50581:2012;Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2;electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2;susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3;susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3;susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3;magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8;electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4;electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4;1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5;conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6;;EFUP 10;RCM;CSA;UL;TÜV;CE;EAC
Application For emergency stop and switch monitoring
Number Of Outputs 3
Terminal Type Screw