8502SEO2V08 3-Phase Type S NEMA Contactor, 208 VAC V Coil, 90 A, 3 Poles
- MFR #:
- 8502SEO2V08
- UPC:
- 785901788034
- Item #:
- 566882
8502SEO2V08 3-Phase Type S NEMA Contactor, 208 VAC V Coil, 90 A, 3 Poles
- MFR #:
- 8502SEO2V08
- UPC:
- 785901788034
- Item #:
- 566882
Product Details
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 3 non-reversing contactor has a 90 ampere rating. Three phase NEMA Size 3 contactors have 25 HP at 200, 30 HP at 230 VAC and 50 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 208 VAC 60 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 7.09 inches tall, 5.47 inches wide and 6.50 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
Manuals and Documentation
Features
- Switch heating loads, capacitors, transformers, and electric motors where overload protection is separately provided
- Robustdesign and reliable build for long mechanical life and electrical endurance
- Serviceableby replacing contacts and coils
Specifications
Identifiers
| Manufacturer Part Number |
8502SEO2V08
|
|---|---|
| GTIN |
00785901788034
|
| UPC |
785901788034
|
|---|---|
| EAN |
0785901788034
|
General Information
| Manufacturer |
Schneider Electric
|
|---|---|
| Brand |
Square Dâ„¢
|
| Country Of Origin |
US
|
| Warranty |
18 months
|
|---|---|
| Standards Approvals |
UL Listed | CSA Certified | ECCN: EAR99 | PROP65: This product can expose you to chemicals including: Antimony oxide and Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
|
| Application |
For non-reversing application applications
|
Dimensions
| Dimensions |
5.47 in W x 6.5 in D x 7.09 in H
|
|---|
| Size |
SZ 3
|
|---|
Technical Information
| Coil Power Rating |
50 hp
|
|---|---|
| Coil Voltage |
208 V AC
|
| Connection Type |
Screw Clamp
|
| Contact Rating |
90 A at 600 V AC
|
| Contact Type |
Non-Reversing
|
| Enclosure Type |
Open
|
| Frequency Rating |
50/60 Hz
|
| Maximum Load Current |
90 A
|
|---|---|
| Mounting Type |
Surface
|
| Number Of Poles |
3
|
| Series |
8502S
|
| Terminal Type |
Screw
|
| Type |
3-Phase Type S
|