Product Details
EATON's power factor correction capacitors and harmonic filters are an essential part of modern electric power systems. Power factor correction capacitors are the simplest and most economical means of increasing the capacity of any power system, minimizing energy losses and correcting load power factor. In addition, power factor penalties can be reduced and power quality can be greatly enhanced. There are several reasons to correct poor power factor. The first is to reduce or eliminate a power factor penalty charged by the utility. Another reason is that your existing transformer is or shortly will be, at full capacity and installing power factor correction capacitors can be a very cost effective solution to installing a brand new service. Depending on the amount of power factor correction (kVAR that needs to be injected into the electrical system to improve the power factor) and the dynamic nature of the load, a fixed or switched capacitor bank may be the best solution. When capacity becomes a problem, the choice of a solution will be dependent upon the size of the increase needed. Like all power quality solutions, there are many factors that need to be considered when determining which solution will be best to solve your power factor problem.
Manuals and Documentation
Features
- Simplest and most economical means of increasing the transmission capacity of a power system, minimizing energy losses and correcting load power factor
- Power factor penalties can be reduced and power quality can be greatly enhanced
- Dry type capacitor cell with threaded terminals for secure connection, 10 kVAC stand-off terminal bushings
- Thermosetting polymer resin dielectric fill, self-healing metallized polypropylene dielectric film
- Built-in, 3-phase pressure sensitive interrupter design, removes capacitor from line before internal pressures can cause case rupture
- Discharge resistor reduces the residual voltage to less than 50 VAC residual within 5 min of de-energization, mounted on terminal stud assemblies
- Losses less than 1/2 W per kV
- Built-in, 3-phase interrupter design
- Removes capacitor from line before internal pressures can cause case rupture
Specifications
Identifiers
| Manufacturer Part Number |
2043PCDMF
|
|---|---|
| GTIN |
00782116097517
|
| UPC |
782116097517
|
|---|
General Information
| Manufacturer |
Eaton
|
|---|---|
| Brand |
EATON
|
| Country Of Origin |
US
|
|---|---|
| Standards Approvals |
UL Listed
|
Dimensions
| Dimensions |
7 in L x 4.59 in W
|
|---|
Technical Information
| Environmental Conditions |
-40 to 46 deg C Temperature
|
|---|---|
| Frequency Rating |
60 Hz
|
| Material |
Steel
|
| Power Rating |
20
|
|---|---|
| Type |
Power Factor Correction
|
| Voltage Rating |
480 V AC
|