Type C Flanged Conduit Body, 3/4 inch, Aluminum, Zinc Electroplated/Chromate/Epoxy Powder Coat
MFR: Appleton Electric
MFR #: GRFC75A
UPC: 781381621786
Item #: 35366
Type C Flanged Conduit Body, 3/4 inch, Aluminum, Zinc Electroplated/Chromate/Epoxy Powder Coat
MFR #: GRFC75A
UPC: 781381621786
Item #: 35366
Availability
| Location | Available Qty |
|---|---|
| Available | Available to Order |
$203.93
each
UNILETS Flanged Outlet Box, Number Of Outlet: 2, Material: Copperfree (4/10 Of 1 PCT Maximum) Aluminum, Size: 3/4 IN, Cable Entry: (2) 3/4 IN GRFC Hub, Cubic Capacity: 18 CU-IN, Knockouts: No, Cover Opening: 3.38 IN, Form Number: 1, Heigh
Manuals and Documentation
Features
- Function as sealing fittings when used with sealing covers
- Internally threaded body with externally threaded cover
- Covers have pry notches for bar or wrench.
- Standard O-rings provide raintight fit NEMA 3, 4
- Smooth, rounded integral bushing in each hub type box protects conductor insulation
- CSA Certified
- UL Listed
- Catalog Number
- GRFC75A
- Manufacturer
- Appleton Electric
- Brand
- Appleton
- Country of Origin
- Mexico
- Made in USA
- No
- Application
- For Use With Threaded Metal Conduit
- Cable Entry
- (2) 3/4 IN GRFC Hub
- Cubic Capacity
- 18 CU IN
- Knockouts
- No
- Material
- Copperfree (4/10 Of 1 PCT Maximum) Aluminum
- Special Features
- Explosionproof, dust-ignitionproof; Accurately tapped, tapered hub threads for tight, rigid joints and ground continuity; Furnished with copperfree (4/10 of 1 PCT maximum) aluminum cover; Function as sealing fittings when used with sealing covers; Internally threaded body with externally threaded cover; Covers have pry notches for bar or wrench; Accommodate sealing, dome, hub and union hub covers and canopies; Standard O-rings provide raintight fit NEMA 3, 4; Internal ground screw standard; Smooth rounded integral bushing in hub box protects conductor insulation; Complies with a wide range of classified area requirements; Corrosion-resistant ideal indoors or out; For pulling of wires; Connect conduit lengths and change direction of conduit runs; Provide access for maintenance
- Standard
- Class 1, Zone 1 And 2 IIA And IIB, UL File Number E10444, CSA C22.2 No. 25, C22.2 No. 30, CSA 013017 Certified, Class I, Division 1 And 2, Groups B, C, D Class II, Division 1 And 2, Groups E, F, G Class III
- RoHS Indicator
- Contact Manufacturer
- UPC
- 781381621786
- GTIN
- 00781381621786
- Item Type
- Flanged Outlet Box
- Length
- 6.5000
- Length UOM
- Inch
- Width
- 8.0000
- Width UOM
- Inch
- Height
- 3.5000
- Height UOM
- Inch
- Weight
- 1.600
- Weight UOM
- Pounds
- Size