S811+V10N3S Non-Combination Reduced Voltage Standard Open Soft Starter, 24 VDC V Coil, Start/Stop Action, 3 Poles, NEMA 1/3R/4/4X/7/9/12 Enclosure
- MFR #:
- S811+V10N3S
- UPC:
- 786685558646
- Item #:
- 1637084
S811+V10N3S Non-Combination Reduced Voltage Standard Open Soft Starter, 24 VDC V Coil, Start/Stop Action, 3 Poles, NEMA 1/3R/4/4X/7/9/12 Enclosure
- MFR #:
- S811+V10N3S
- UPC:
- 786685558646
- Item #:
- 1637084
Product Details
Advanced intelligence. Compact footprint. The S811+/S801+?line of?intelligent?technologies?soft?starters is designed to be the smallest, most compact soft starter in the market today. With this small size, it can easily fit in place of existing soft starter designs, wye-delta starters or across-the-line NEMA and IEC starters. This feature allows easy retrofits of existing motor control centers or enclosures and saves the expense of replacing existing structures or adding a new one to house a soft starter. The product is designed to work with 3-phase motors in a Delta (3-lead) configuration. The S811/S811+ works with all motors from fractional horsepower up to motors requiring 1000 amps of steady state current. The built-in over-load (in ranges from 12 - 1000 amps) and run bypass contactor make installation and setup quick and easy. The overload also offers some advanced protective functions to give additional motor protection. With the pump control option, it is the number one soft starter available for pumping applications. The unique soft stopping control provides a smooth transition for stopping a motor and eliminating the "water-hammer" effect that can damage pipes, valves and pumps.
Manuals and Documentation
Features
- Communication capabilities with various protocols
- The digital interface module (DIM) provides an intuitive, easy to use human interface with powerful configuration capabilities to maximize system performance
- Door or device mounted UI enables users to safely configure, commission, monitor and troubleshoot the system at the electrical panel without opening the enclosure door, eliminating the possibility of an arc flash incident
- System operating parameters can be monitored enterprise wide through a communications network, increase uptime by providing data for process management and preventive diagnostics
- Run internal bypass mode greatly reduces internal heating created by the greater power dissipation in the SCRs, bypass contactor directly connects the motor to the line and improves system efficiency by reducing internal power losses
- Internal solid state overload protection provides accurate current measurement and trip settings, sophisticated algorithms solve a series of differential equations that model true motor heating and cooling, resulting in superior motor overload protection while minimizing nuisance trips
- Advanced selectable protective features safeguard the motor and system against a variety of system faults
- Internal run bypass contactors and overload protection eliminate the need for additional devices, reducing enclosure sizes minimizing installation and wiring time and reducing overall assembly size and cost
- Wide range of overload FLA settings (31 to 100% of rated current) and a selectable trip class (5 to 30) offers users the flexibility to fine tune the starter to match specific application requirements
- Variable ramp times and torque control settings provide unlimited starting configurations, allowing for maximum application flexibility
- Kick start feature enables soft starting of high friction loads
- Soft stop control for applications where an abrupt stop of the load is not acceptable
- The S811+ premium with sophisticated pump control algorithms on both starting and stopping that minimize the pressure surges that cause water hammer, the pump control feature will maximize the life of the pump and piping systems while minimizing the downtime caused by system failure
- Six SCRs control all three motor phases, providing smooth acceleration and deceleration performance
- Soft acceleration and deceleration reduces wear on belts, gears, chains, clutches, shafts and bearings
- Reduce the peak inrush current stress on the power system, manage peak starting torque to diminish mechanical system wear and damage
- 24 VDC control voltage enhances personnel and equipment safety
- Removable, lockable control terminal block reduces maintenance costs, also provides the opportunity for OEMs to reduce assembly and test costs by utilizing pre-assembled wire harnesses
- 400/350 hp at 230 V, 800/700 hp at 460 V, 900/800 hp at 575 to 690 V
Specifications
Identifiers
| Manufacturer Part Number |
S811+V10N3S
|
|---|---|
| GTIN |
00786685558646
|
| UPC |
786685558646
|
|---|
General Information
| Manufacturer |
Eaton
|
|---|---|
| Brand |
EATON
|
| Country Of Origin |
DO
|
| Standards Approvals |
Contact Manufacturer
|
|---|---|
| Application |
Electrical Assemblies, Panels and EOEMs Applications
|
Dimensions
| Dimensions |
22.1 x 17.2 x 11.7 in
|
|---|
Technical Information
| Action |
Start/Stop
|
|---|---|
| Amperage Rating |
105 A
|
| Coil Voltage |
24 V DC
|
| Connection Type |
In-Line/Delta/Add-on Lug Kit
|
| Enclosure Type |
NEMA 1/3R/4/4X/7/9/12
|
| Frequency Rating |
47 to 63 Hz
|
| Full Load Current |
320 to 1000 A
|
| Motor Power |
900 hp
|
| Number Of Poles |
3
|
| Operating Temperature |
-30 to 50 deg C
|
|---|---|
| Overload Relay |
Solid-State
|
| Phase |
3
|
| Series |
S811+
|
| Setting |
30 to 100%
|
| Starting Modes |
Soft Start/Current Limit/Kick Start/Ramp Start/Soft Stop
|
| Timing |
0.5 to 180 s
|
| Type |
Non-Combination Reduced Voltage Standard
|
| Voltage Rating |
200 to 600 V AC
|