EDR-5000-2A0BA1 Current/Voltage/Power Protection Distribution Relay, 40 to 250 V AC, 19 to 300 V DC Supply, 8 Inputs, 11 Outputs, Digital Input, Digital Output
- MFR #:
- EDR-5000-2A0BA1
- UPC:
- 786679144541
- Item #:
- 1534846
EDR-5000-2A0BA1 Current/Voltage/Power Protection Distribution Relay, 40 to 250 V AC, 19 to 300 V DC Supply, 8 Inputs, 11 Outputs, Digital Input, Digital Output
- MFR #:
- EDR-5000-2A0BA1
- UPC:
- 786679144541
- Item #:
- 1534846
Product Details
Eaton’s Distribution Relays (EDR3000 and EDR5000) offer complete metering, protection, and control for all voltages in a single compact case to reduce panel space, wiring and overall costs. All relays meet or exceed instantaneous and time overcurrent requirements. Integral test functions reduce required maintenance and troubleshooting time, and intuitive programming reduces required operator training time and provides unmatched flexibility, resulting in reduced overall expense. All relays perform multiple protection functions, self-diagnostics, and reporting for transformers and distribution lines.
Manuals and Documentation
Features
- Complete metering, protection and control in a single compact case to reduce panel space, wiring and costs
- Intuitive programming substantially reduces operator training time and provides unmatched operability and flexibility
- Integral test function reduces maintenance time and expense
- Zone selective interlocking improves coordination and tripping time and saves money compared to a traditional bus differential scheme
- Multiple operator selectable protective functions reduce arc flash energy and zone selective interlocking for bus protection, eliminating the need of additional CTs or relays
- Reduce troubleshooting time and maintenance costs-trip and event recording in non-volatile memory provides detailed information for analysis and system restoration, 6000 cycles of waveform capture aids in post fault analysis (viewable using Powerport-E software)
- Minimum replacement time-removable terminal blocks ideal in industrial environments
- Breaker open/close from relay faceplate or remotely via communications
- Fast and easy troubleshooting, improved maintenance procedures and increased device security, provides detailed traceability for system configuration changes
- Relays self-diagnostics and reporting improves uptime and troubleshooting
- Breaker trip circuit monitoring improves the reliability of the breaker operation
- 5/1 A phase and ground current
- Modbus/DNP3 RTU over RS-485 communication
- Removable terminals, zone interlocking
Specifications
Identifiers
| Manufacturer Part Number |
EDR-5000-2A0BA1
|
|---|---|
| GTIN |
00786679144541
|
| UPC |
786679144541
|
|---|
General Information
| Manufacturer |
Eaton
|
|---|---|
| Brand |
EATON
|
| Country Of Origin |
US
|
| Standards Approvals |
ANSI C37.90 | BAA Compliant | CSA C22.2 No 14-95 | EN 50178 | EN 61000-6-2 | EN 61000-6-3 | IEC 60255-6 | UL 508/File E217753
|
|---|---|
| Application |
Distribution Feeder Protection, Primary or Backup Transformer Protection, Generators, Utility Interconnections and Transfer Schemes
|
Dimensions
| Dimensions |
8.05 in L x 9.72 in W x 8.7 in H
|
|---|
Technical Information
| Amperage Rating |
5 A
|
|---|---|
| Display Type |
LCD
|
| Input Type |
Digital
|
| Material |
Aluminum
|
| Mounting Type |
Projection Panel
|
| Number Of Inputs |
8
|
| Number Of Outputs |
11
|
|---|---|
| Output Type |
Digital
|
| Series |
EDR-5000
|
| Supply Voltage |
40 to 250 V AC, 19 to 300 V DC
|
| Temperature Rating |
-4 to 140 deg F
|
| Type |
Current/Voltage/Power Protection
|