A6D6R Amp-Trap 2000 SmartSpot Current Limiting Low Voltage North American Time Delay Power Fuse, 6 A, 600 V AC, 200 kA Interrupt, RK1 Class, Cylindrical Body

MFR #:
A6D6R
UPC:
782001991753
Item #:
143257
$99.94 each
Product Details

Amp-Trap 2000® time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Manuals and Documentation

Features

  • Solid state SmartSpot® indicator
  • Time delay for motor starting and transformer inrush currents without nuisance opening
  • 300 kA interrupting rating, self certified (UL witnessed)
  • Extremely current limiting for low peak let-thru current
  • Easy 2-to-1 selectivity for prevention of nuisance shutdowns and "blackouts"
  • Rejection style design prevents replacement errors (when used with recommended fuse blocks)
  • High visibility orange label gives instant recognition
  • Reduced inventory by taking the place of class RK5, K and H fuses
  • Metal embossed date and catalog number for easier traceability and lasting identification
  • Fiberglass body provides dimensional stability in harsh industrial settings
  • High grade silica filler ensures fast arc quenching
  • Recommended for arc flash energy reduction
  • A6D-R fuses will open fast enough under extreme fault conditions for maximum short
  • Plated terminals
  • Arc flash mitigating
  • Tin-plated copper contact

Specifications

Identifiers

Identifiers
Manufacturer Part Number
A6D6R
GTIN
00782001991753
Identifiers
UPC
782001991753

General Information

General Information
Manufacturer
MERSEN
Brand
Mersen
Country Of Origin
MX
General Information
Standards Approvals
CSA C22.2 No. 248.12 | DC Listed | UL 248 | UL 248-12 File No. E2137
Application
Motor, Safety Switches, Transformers, Disconnects, Control Panel and All General Purpose Circuits Applications

Technical Information

Technical Information
Amperage Rating
6 A
Body Size
13/16 in Dia x 5 in L
Body Type
Cylindrical
Class
RK1
Element
Dual
Indicating Non Indicating
Indicating
Interrupt Rating
200 kA
Technical Information
Material
Fiberglass
Mounting Type
Clip
Rejection Non Rejection
Rejection
Series
A6D-R
Terminal Type
Ferrule
Type
Current Limiting Low Voltage North American Time Delay
Voltage Rating
600 V AC