Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
Manuals and Documentation
Features
- Provides motor overload, ground fault and short circuit protection
- Helps protect motors against burnout from overloads and 1 ph when sized properly
- Simplifies and improves blackout prevention (selective co-ordination ratios)
- Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is 5X greater than the amperage rating of the fuse for a minimum of 10 s
- Superior overload and cycling capabilities
- True dual element construction allows sizing of 125% FLA for motor backup protection
- Current limiting provides component short circuit protection
- For all general purpose applications including lighting, heating and other non-inductive loads
- Tin plated copper brass terminal and zinc plated steel screws
Specifications
Identifiers
| Manufacturer Part Number |
ECNR600
|
|---|---|
| GTIN |
00782634507567
|
| UPC |
782634507567
|
|---|
General Information
| Manufacturer |
Eaton
|
|---|---|
| Brand |
Edison
|
| Country Of Origin |
MX
|
| Standards Approvals |
CE Certified | CSA C22.2 File No.700489/248.12 | UL 248-12 File No.E162363 Guide JDDZ
|
|---|---|
| Application |
Industrial Facilities and Factories, Safety and Security Systems, AC Power Distribution System Mains, Feeders, Branch Circuits, Motor, Motor Branch Circuits, Transformers and Other Inductive Loads Applications
|
Technical Information
| Amperage Rating |
600 A
|
|---|---|
| Body Size |
2.88 in Dia x 10.38 in L
|
| Body Type |
Cylindrical
|
| Class |
RK5
|
| Element |
Dual
|
| Indicating Non Indicating |
Non-Indicating
|
| Interrupt Rating |
200 kAIC
|
| Material |
Fiberglass
|
|---|---|
| Rejection Non Rejection |
Rejection
|
| Response Time |
10 s at 500%
|
| Series |
ECNR
|
| Terminal Type |
Blade End
|
| Type |
Current Limiting Time Delay
|
| Voltage Rating |
250 V AC/125 V DC
|