ECSR17.5 Bullet Current Limiting Time Delay Fuse, 17.5 A, 600 V, 200 kAIC Interrupt, RK5 Class, Cartridge Body
- MFR #:
- ECSR17.5
- Item #:
- 1091611
ECSR17.5 Bullet Current Limiting Time Delay Fuse, 17.5 A, 600 V, 200 kAIC Interrupt, RK5 Class, Cartridge Body
- MFR #:
- ECSR17.5
- Item #:
- 1091611
Product Details
These fuses are recommended for AC power distribution system mains, feeders and branch circuits having inductive loads (motors, transformers) or non-inductive loads (lighting, heating) where the available short circuit current does not exceed 200000 RMS symmetrical amperes. These dual element, time delay fuses have minimum industry standard time delay of 10 s at 5 times the fuse rating (8 s minimum for 250 VAC, 30 A and less). The time delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved over current protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. They are the most popular fuses used in the industry and the most economical for most applications, especially motors and transformers. They have moderate current limitation.
Manuals and Documentation
Features
- True dual element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Current limiting provides component short circuit protection
- For all general purpose applications including lighting, heating and other non-inductive loads
- Tin plated copper brass terminal and zinc plated steel screws
Specifications
Identifiers
| Manufacturer Part Number |
ECSR17.5
|
|---|
General Information
| Manufacturer |
Eaton
|
|---|---|
| Brand |
Edison
|
| Country Of Origin |
MX
|
| Standards Approvals |
UL E162363, Guide JDDZ | CSA C22.2, No. 248.12 | Class 1422-02, File No. 700489 | CE Certified
|
|---|---|
| Application |
AC Power Distribution System Mains, Feeders, Branch Circuits, Motor, Motor Branch Circuits, Transformers, Other Inductive Loads, Lighting, Heating and Other Non-inductive Loads Applications
|
Technical Information
| Amperage Rating |
17.5 A
|
|---|---|
| Body Size |
0.81 in Dia x 5 in L
|
| Body Type |
Cylindrical
|
| Class |
RK5
|
| Element |
Dual
|
| Indicating Non Indicating |
Non-Indicating
|
| Interrupt Rating |
200 kA
|
| Material |
Fiberglass
|
|---|---|
| Rejection Non Rejection |
Rejection
|
| Response Time |
10 s at 500%
|
| Series |
ECSR
|
| Terminal Type |
Ferrule
|
| Type |
Current Limiting
|
| Voltage Rating |
600 V AC
|